Reset Quota
The Reset Quota policy can be used to reset the quota limit of a user. This helps in cases where a quota needs to be reset for a particular user using the administration API.
Configuration
The properties that have to be configured to use the policy are described below.
Figure 1: Reset Quota Policy Configuration property values based on Quota policy values
Click the Edit icon corresponding to the above properties to configure Type, Variable Name and Default Value for the corresponding properties.
Figure 2: Dialog box to choose Identifier Type
Refer to the Configuring Message Part Identifier section to configure these parameters.
Property | Description |
Quota Identifier | The Quota Identifier field value as configured in the Quota policy. |
API Project Name | Name of the project in which quota policy is used. |
API Project Version | The version of the project in which quota policy is used. |
Deployed Environment | The environment in which the project containing quota policy is deployed. |
Quota Policy Name | Name as configured in the Quota policy |
Distributed | This option is used to fetch data from the distributed database (Cassandra). If disabled, it fetches data from the cache memory in the local machine. |
Synchronous | Specifies that the remaining quota value gets updated after every call. This option is suggested when the quota value is a hard limit to the number of calls that can be made. The Synchronous option gets enabled when the Distributed option is enabled.
|
Example
Configure the policy with the details below:
- Quota Identifier:
- Type: PARAMETER
- Variable Name: clientId (ID of the client making the request)
Default Value: default (any value)
This Quota Identifier should be the same as the quota identifier defined in the Quota policy.
API Project Name:
- Type: PARAMETER
- Variable Name: projectName
- Default Value: default (any value)
- API Project Version:
- Type: PARAMETER
- Variable Name: projectVersion
- Default Value: default (any value)
Deployed Environment:
- Type: PARAMETER
- Variable Name: environmentName
- Default Value: default (any value)
- Quota Policy Name:
- Type: PARAMETER
- Variable Name: QuotaPolicyName
- Default Value: default (any value)
Figure 3: Reset Quota policy configured with values as provided in the Example
When the quota limit of a client for a project exceeds the set limit, an administrative tool can send a request to the project containing the policy that is set with appropriate parameters to reset the quota so that the client will have a chance to send requests in special cases.